{"id":324,"date":"2026-11-17T16:27:45","date_gmt":"2026-11-17T08:27:45","guid":{"rendered":"https:\/\/dwgsee.com\/cad\/support\/?post_type=docs&#038;p=324"},"modified":"2026-11-17T16:29:44","modified_gmt":"2026-11-17T08:29:44","password":"","slug":"dimchamfer","status":"publish","type":"docs","link":"https:\/\/www.dwgsee.com\/cad\/support\/docs\/dimchamfer\/","title":{"rendered":"DIMCHAMFER"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">DIMCHAMFER<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Overview<\/h3>\n\n\n\n<p>The DIMCHAMFER command in DWGSeeCAD creates dedicated chamfer dimension annotations for mechanical drawings. It opens the Dim Chamfer dialog box, where you can set chamfer text content, text height and suffix options. This command is designed specifically for marking chamfer sizes, and it is a DWGSeeCAD extended command.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Command Prompt Workflow<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Enter DIMCHAMFER on the command line and press Enter.<\/li>\n\n\n\n<li>Prompt: <strong>[Dim chamfer ] Select the line to dimension<\/strong>: Pick the chamfer edge you want to label.<\/li>\n\n\n\n<li>The Dim Chamfer dialog pops up.\n<ul class=\"wp-block-list\">\n<li>Top input box: Enter or modify chamfer dimension text, such as 163.59X90.<\/li>\n\n\n\n<li>Text Height: Set the height of the chamfer annotation text.<\/li>\n\n\n\n<li>Suffix plus: Check this option to automatically add standard suffix for chamfer marking.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Click OK to confirm the settings.<\/li>\n\n\n\n<li>Prompt: <strong>[Dim chamfer ] Specify dimension position:<\/strong> Click the location to place the chamfer dimension text.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Dialog Options<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Chamfer Text Input<\/strong>: Custom chamfer label content, usually formatted as length \u00d7 angle for chamfer notation.<\/li>\n\n\n\n<li><strong>Text Height<\/strong>: Controls the display size of the chamfer annotation text.<\/li>\n\n\n\n<li><strong>Suffix plus<\/strong>: Enable this checkbox to append standard chamfer suffix automatically.<\/li>\n\n\n\n<li><strong>OK \/ Cancel<\/strong>: Save and place the dimension, or discard the operation.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Usage Notes<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DIMCHAMFER is a dedicated chamfer dimension tool, different from standard linear or angular dimension commands.<\/li>\n\n\n\n<li>It supports custom chamfer text format to match mechanical drawing standards for chamfer notation.<\/li>\n\n\n\n<li>You can adjust text height independently for chamfer labels, separate from your global dimension style settings.<\/li>\n\n\n\n<li>This is a custom DWGSeeCAD extended command, not built into native AutoCAD.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Application Scenarios<\/h3>\n\n\n\n<p>Use DIMCHAMFER on mechanical part drawings to quickly add standardized chamfer annotations. It is widely used for machining drawings, mold drawings and component detail drawings where chamfer size marking is required.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>DIMCHAMFER Overview The DIMCHAMFER command in DWGSeeCAD creates dedicated chamfer dimension annotations for mechanical drawings. It opens the Dim Chamfer dialog box, where you can set chamfer text content, text height and suffix options. This command is designed specifically for marking chamfer sizes, and it is a DWGSeeCAD extended command. Command Prompt Workflow Dialog Options&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"doc_category":[108],"doc_tag":[17],"class_list":["post-324","docs","type-docs","status-publish","hentry","doc_category-dimension-objects","doc_tag-dimension"],"year_month":"2026-11","word_count":282,"total_views":"5","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"autodwg","author_nicename":"autodwg","author_url":"https:\/\/www.dwgsee.com\/cad\/support\/author\/autodwg\/"},"doc_category_info":[{"term_name":"Dimension Objects","term_url":"https:\/\/www.dwgsee.com\/cad\/support\/docs-category\/dimension-objects\/"}],"doc_tag_info":[{"term_name":"Dimension","term_url":"https:\/\/www.dwgsee.com\/cad\/support\/docs-tag\/dimension\/"}],"_links":{"self":[{"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/docs\/324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/comments?post=324"}],"version-history":[{"count":3,"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/docs\/324\/revisions"}],"predecessor-version":[{"id":1105,"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/docs\/324\/revisions\/1105"}],"wp:attachment":[{"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/media?parent=324"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/doc_category?post=324"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.dwgsee.com\/cad\/support\/wp-json\/wp\/v2\/doc_tag?post=324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}